| Dimensions W x L x H | 45 mm x 170 mm x 35 mm |
|---|---|
| KC characters | KC EMC |
| Fieldbus interface, connection technology | M12x1, D-coded as per EN 61076-2-101 |
| Diagnose per internal communication | Module errorOutput short circuit/overloadShort circuit/overload in sensor supplyLoad supply undervoltage |
| Max. power supply | 2 x 4 A (external fuse required) |
| Note on degree of protection | Unused connections sealed |
| Communication interface, connection technology | M8x1, D-coded as per EN 61076-2-114 |
| Fieldbus interface, connection type | 2x socket |
| Permissible voltage fluctuations for electronics/sensors | ± 25 % |
| Fieldbus interface, type | Ethernet |
| Power supply, connection technology | M8x1, A-coded as per EN 61076-2-104 |
| Power supply, function | Incoming electronics/sensors and load |
| Fieldbus interface, function | Bus connection, incoming/forwarding |
| Information on max. cable length | Power supply according to nominal voltage |
| Intrinsic current consumption at nominal operating voltage load | Typically 5 mA |
| Voltage forwarding, connection technology | M8x1, A-coded as per EN 61076-2-104 |
| Diagnostics via bus | Load switch-offLoad overvoltageLoad undervoltageElectronics/sensors overvoltageElectronics/sensors undervoltageAPDD invalidCommunication with AP module interrupted |
| Relative air humidity | 5 – 95 %Non-condensing |
| Fieldbus interface, galvanic isolation | yes |
| Communication interface, connection type | 2x socket |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 90 mA |
| Power supply, type of connection | Plug |
| Voltage forwarding, connection type | Socket |
| Communication interface, function | System communication XF20 OUT / XF21 OUT |
| Fieldbus interface, protocol | EtherCAT |
| Configuration support | ESI file |
| Max. cable length | 50 m system communication |
| Communication interface, protocol | AP-COM |
| Fieldbus interface, transmission rate | 100 Mbit/s |
| Diagnostics via LED | Diagnostics per moduleEtherCAT RUNPower supply for electronics/sensorsLoad power supplySystem diagnosticsMaintenance required |
| Permissible voltage fluctuations load | ± 25 % |
| Communication interface, shielding | yes |
| Voltage forwarding, function | Outgoing electronics/sensors and load |
| Fieldbus interface, number of poles/wires | 4 |
| Max. address capacity outputs | 2048 byte |
| Voltage forwarding, number of pins/wires | 4 |
| Nominal operating voltage DC for electronics/sensors | 24 V |
| Power supply, number of pins/wires | 4 |
| Max. address capacity inputs | 2048 byte |
| Communication interface, number of pins/wires | 4 |
| Nominal operating voltage DC load | 24 V |
| Power failure buffering | 10 ms |
| Max. number of modules | 80 |
| Note regarding operating voltage | SELV/PELV fixed power supplies requiredNote voltage drop |
| Type code | CPX-AP-I |
| Reverse polarity protection | yes |
| CE marking (see declaration of conformity) | As per EU EMC directive |
| Corrosion resistance class (CRC) | 1 – Low corrosion stress |
| Storage temperature | -40 °C … 70 °C |
| Degree of protection | IP65IP67 |
| Ambient temperature | -20 °C … 50 °C |
| Certification | RCM compliance mark |
| Product weight | 186 g |
| Type of mounting | With through-hole |
| Note on materials | RoHS-compliant |
| Housing material | PAPCDie-cast zinc, nickel-plated |
| Weight | 0.466189 lbs |
|---|---|
| Dimensions | 6.889764 × 1.968504 × 1.574803 in |
Only logged in customers who have purchased this product may leave a review.




Reviews
There are no reviews yet