Dimensions W x L x H | 42.2 mm x 125.8 mm x 76.5 mm |
---|---|
Power supply, type of connection | Terminal strip |
Vibration resistance | Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6 |
Ethernet interface, protocol | TCP/IPEasyIPModbus® TCP |
Fieldbus interface, connection type | Socket |
Note on ambient temperature | -5 – 60 °C for vertical installation |
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 65 mA |
Ethernet interface, connection technology | RJ45 |
Fieldbus interface, connection pattern | 995789 |
Power supply, connection pattern | 995847 |
Fieldbus interface, function | Bus connection, forwarding |
Ethernet interface, transmission rate | 10 Mbit/s100 Mbit/s |
Power supply, function | Electronics and sensors |
Power supply, information on conductor diameter | 0.2 – 2.5 mm² for flexible conductors without cable end sleeves |
Ethernet interface, function | Diagnostics |
Permissible voltage fluctuations for electronics/sensors | ± 25 % |
System parameter | Diagnostic memorySystem startFail-safe response |
Ethernet interface, connection pattern | 995789 |
Fieldbus interface, connection technology | RJ45 |
Power supply, connection technology | Spring-loaded terminal |
Fieldbus interface, protocol | EtherCAT Master |
Shock resistance | Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27 |
Module parameters | Analog module process value representationChannel alarm bundlingChannel alarms for undervoltageUndervoltage diagnostics |
Diagnostics via LED | EtherCAT network statusPower supply for electronics/sensorsForce modeRunLoad power supplyNetwork status, engineering port 1System fault |
Ethernet interface, number of poles/wires | 8 |
Nominal operating voltage DC for electronics/sensors | 24 V |
Power supply, number of pins/wires | 4 |
Fieldbus interface, number of poles/wires | 8 |
Max. number of modules | 10 |
Power supply, conductor diameter | 0.2 mm² … 1.5 mm² |
Width dimension | 18.9 mm |
Type code | CPX-E |
CPU data | 512 MB RAMDual core 666 MHz |
Configuration support | CODESYS V3 |
Additional functions | CODESYS V3 |
Control elements | DIL switch for RUN/STOP |
Processing time | Approx. 200 µs/1 k instruction |
IP address setting | DHCPVia CODESYS |
Function blocks | Copying of CPX-E diagnostic traceand othersRead CPX-E module diagnosticsCPX-E diagnostic status |
Max. power supply | 0.333333333333333 |
Flag | CODESYS variable concept120 kB remanent data |
Power failure buffering | 20 ms |
Programming software | CODESYS provided by Festo |
Program memory | 12 MB user program |
CE marking (see declaration of conformity) | As per EU EMC directive |
Corrosion resistance class (CRC) | 0 – No corrosion stress |
Storage temperature | -20 °C … 70 °C |
Relative air humidity | Non-condensing95 % |
Protection against direct and indirect contact | PELV |
Degree of protection | IP20 |
Ambient temperature | -5 °C … 50 °C |
Certification | c UL us – Listed (OL)RCM compliance mark |
Product weight | 145 g |
Max. address capacity outputs | 64 byte |
Max. address capacity inputs | 64 byte |
Fieldbus interface, galvanic isolation | yes |
Fieldbus interface, transmission rate | 100 Mbit/s |
Fieldbus interface, type | Ethernet |
Type of mounting | With H-rail |
Note on materials | Contains paint-wetting impairment substancesRoHS-compliant |