input module CPX-F8DE-P Dimensions W x L x H=(* (incl. interlinking block and connection technology), * 50 mm x 107 mm x 55 mm), No. of inputs=8, Diagnosis=(* – Wire break per channel, * – Communication, * – Short circuit per channel, * – Process data error, * – Crossover per channel, * – Self-test, * – Overvoltage, * – Overtemperature, * – Undervoltage), Safety function=Reliable detection and evaluation of input statuses, Safety Integrity Level (SIL)=(* Reliable detection and evaluation of input statuses in accordance with EN 62061 up to SIL CL3, * Reliable detection and evaluation of input statuses in accordance with EN61508 up to SIL CL3)
| Dimensions W x L x HÂ | (incl. interlinking block and connection technology)50 mm x 107 mm x 55 mm |
|---|---|
| No. of inputs | 8 |
| Diagnosis | ‘- Wire break per channel- Communication- Short circuit per channel- Process data error- Crossover per channel- Self-test- Overvoltage- Overtemperature- Undervoltage |
| Safety function | Reliable detection and evaluation of input statuses |
| Safety Integrity Level (SIL)Â | Reliable detection and evaluation of input statuses in accordance with EN 62061 up to SIL CL3Reliable detection and evaluation of input statuses in accordance with EN61508 up to SIL CL3 |
| Performance level (PL)Â | Reliable detection and evaluation of input statuses in accordance with ISO 13849 up to cat. 4 and PL e |
| Control elements | DIL switches |
| LED displays | ‘- 1 Failsafe protocol active- 1 Group diagnosis- 8 Channel diagnosis- 8 Channel status |
| Operating voltage range DCÂ | 20.4 … 28.8 V |
| Intrinsic current consumption at operating voltage | Typically 35 mA for electronics |
| Max. resultant current per module | 0.125 |
| Nominal operating voltage DCÂ | 24 V |
| Electrical isolation channel – channel | No |




Reviews