adding counter PZA-A-B Design structure=mechanical sequence counter with pneumatic drive, Type of reset=Pushbutton or pneumatic signal, Display=6-place, Release pressure, drive unit=0,2 ± 0,1 bar, Release pressure, return=0,15 ± 0,1 bar
| Design structure | mechanical sequence counter with pneumatic drive |
|---|---|
| Type of reset | Pushbutton or pneumatic signal |
| Display | 6-place |
| Release pressure, drive unit | 0,2 ± 0,1 bar |
| Release pressure, return | 0,15 ± 0,1 bar |
| Response pressure, drive unit | 0,6 ± 0,2 bar |
| Response pressure, return | 0,6 ± 0,2 bar |
| Operating pressure | 2 … 8 bar |
| Minimum reset pressure | 2 bar |
| Minimum pulse length, drive unit | 10 ms |
| Minimum pulse length, return | 180 ms |
| Minimum pause period, drive unit | 15 ms |
| Minimum pause period, return | 50 ms |