electrical interface CPV14-GE-DI02-8 CP string extension=(* Yes, * 32 inputs, * 32 outputs), Fieldbus interface=(* Optional, * – Socket and plug, M12x1, 5-pin, B coded, * – Sub-D, 9-pin, socket), Device-specific diagnostics=(* via device-relating diagnosis (DPV0) , * Missing module on CP string extension, * Short-circuit / overload, outputs, * Undervoltage, outputs, * Undervoltage, sensor supply power, * Undervoltage, valves), Communication types=Cyclical communication, Configuration support=DDB file and bitmaps
| CP string extension | Yes32 inputs32 outputs |
|---|---|
| Fieldbus interface | Optional- Socket and plug, M12x1, 5-pin, B coded- Sub-D, 9-pin, socket |
| Device-specific diagnostics | via device-relating diagnosis (DPV0) Missing module on CP string extensionShort-circuit / overload, outputsUndervoltage, outputsUndervoltage, sensor supply powerUndervoltage, valves |
| Communication types | Cyclical communication |
| Configuration support | DDB file and bitmaps |
| Maximum number of solenoid coils with string extension | 48 |
| Max. number of solenoid coils | 16 |
| Polarity protected | for all electrical connections |
| Baud rate | 9,6 kBaud … 12 MbaudAutomatic detection |
| Operating voltage range DCÂ | 20.4 … 26.4 V |
| Maximum number of outputs | 16 solenoid coils and 32 outputs48 valve coils |
| Maximum number of inputs | 32 |
| Nominal operating voltage DCÂ | 24 V |