SPAU-P10R-MS4-F-L-PNLK-PNVBA-M12D

$248.28

Uniquely flexible in its connection: the pressure sensor SPAU. Whether for pressure measuring, pressure monitoring, or pressure sensing—all pressure values are visible for checking at all times. In IO-Link® mode, remote maintenance and parameterization are possible as well as simple sensor replication.

SKU: 8035304 Category: Tag: Brand:
Type codeSPAU
Electrical connection 1, connection technologyM12x1 A-coded as per EN 61076-2-101
Electrical connection for input 1, connection pattern995386
KC charactersKC EMC
Electrical connection 1, connection typePlug
Electrical connection 1, number of pins/wires4
Symbol995410
CertificationRCM compliance mark
CE marking (see declaration of conformity)As per EU EMC directiveAs per EU RoHS directive
Note on materialsRoHS-compliant
Measured variableRelative pressure
Method of measurementPiezoresistive pressure sensor
Pressure measuring range initial value0 bar
Pressure measuring range end value10 bar
Max. overload pressure15 bar
Operating mediumCompressed air as per ISO 8573-1:2010 [7:4:4]Inert gas
Information on operating and pilot mediaOperation with oil lubrication possible
Temperature of medium0 °C … 50 °C
Ambient temperature0 °C … 50 °C
ADC resolution12 bit
Accuracy in ± % FS1.5 %FS
Repetition accuracy in ± %FS0.3 %FS
Temperature co-efficient in ± %FS/K0.05 %FS/K
Switching functionFreely programmable
Switching element functionN/C contact/N/O contact switchable
Max. output current100 mA
Analog output0 – 10 V4 – 20 mA1 – 5 V
Rise time3 ms
Max. load resistance of current output500 Ohm
Min. load resistance of voltage output10 kOhm
Short-circuit protectionyes
ProtocolIO-Link®
IO-Link®, protocol versionDevice V 1.1
IO-Link®, profileSmart sensor profile
IO-Link®, function classesBinary data channel (BDC)Teach channelProcess data variable (PDV)IdentificationDiagnostics
IO-Link®, communication modeCOM2 (38,4 kBd)
IO-Link®, SIO mode supportYes
IO-Link®, port classA
IO-Link®, process data width OUT0 Byte
IO-Link®, process data width IN2 Byte
IO-Link®, process data content IN14 bit PDV (pressure measurement)2 bit BDC (pressure monitoring)
IO-Link®, minimum cycle time3 ms
IO-Link®, data memory required500 byte
DC operating voltage range20 V … 30 V
Reverse polarity protectionfor all electrical connections
Type of mountingOn service unit
Mounting positionAny
Pneumatic connectionFlange
Product weight80 g
Display typeIlluminated LCD
Displayable unit(s)MPabarinchH2OinchHgkPammHgkgf/cm²psi
Setting optionsIO-Link®Teach-inVia display and pushbuttons
Protection against tamperingIO-Link®PIN code
Threshold value setting range0 % … 100 %
Hysteresis setting range0 % … 90 %
Degree of protectionIP65
Corrosion resistance class (CRC)2 – Moderate corrosion stress