| Dimensions W x L x H | 18.9 mm x 76.6 mm x 124.3 mm |
|---|---|
| Vibration resistance | Transport application test with severity level 1 as per FN 942017-4 and EN 60068-2-6 |
| Electrical connection input, function | Analog input |
| Note on ambient temperature | -5 – 60 °C for vertical installation |
| Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 70 mA |
| Electrical connection for input, information on conductor cross section | 0.2 – 2.5 mm² for flexible conductors without cable end sleeves |
| Diagnostics via bus | Lower limit value not complied withParameter errorParameterization errorSensor supply short circuit/overloadUnderflow/overflowUpper limit value violatedWire breakOverload at analog inputs |
| Permissible voltage fluctuations for electronics/sensors | ± 25 % |
| Electrical input connection, connection technology | Spring-loaded terminal |
| Shock resistance | Shock test with severity level 1 as per FN 942017-5 and EN 60068-2-27 |
| Signal range | -20 – 20 mA0 – 20 mA0 – 10 V-5 – 5 V1 – 5 V-10 – 10 V4 – 20 mA |
| Electrical connection input, connection type | 4x terminal strip |
| Module parameters | Analog input overload diagnosticsResponse to analog input overloadAnalog input data formatSensor supply short circuit diagnosticsLimit monitoring hysteresisResponse to short circuit/overloadDeactivate sensor supplyParameterization error diagnostics |
| Channel parameters | Wire break diagnosticsSignal range per channelUpper limit diagnosticsLower diagnostic limitUnderflow/overflow diagnosticsParameter error diagnosticsSmoothing factorLower/upper limit |
| Diagnostics via LED | Faults per channelFaults per module |
| Electrical connection input 2, function | Functional ground |
| Electrical connection input 2, connection type | Terminal strip |
| Electrical connection for input 2, information on conductor cross section | 0.2 – 2.5 mm² for flexible conductors without cable end sleeves |
| Electrical input 2 connection, connection technology | Spring-loaded terminal |
| Electrical connection for input 2, connection pattern | 995842 |
| Nominal operating voltage DC for electronics/sensors | 24 V |
| Electrical connection, input, number of pins/wires | 4 |
| Electrical connection, input 2, number of pins/wires | 4 |
| Electrical connection for input 2, conductor cross section | 0.2 mm² … 1.5 mm² |
| Width dimension | 18.9 mm |
| Type code | CPX-E |
| No. of inputs | 4 |
| Measured variable | VoltageCurrent |
| Repetition accuracy | ±0.1 % at 25 °C |
| Fuse protection (short circuit) | Internal electronic fuse per module |
| Operating error limit related to the ambient temperature range | +/- 0.3 % |
| Basic error limit at 25°C | +/- 0.2 % |
| Max. residual current of inputs per module | 1.4 A |
| Power failure buffering | 10 ms |
| Electrical isolation between channel and internal bus | yes |
| Electrical isolation between channels | no |
| CE marking (see declaration of conformity) | As per EU EMC directive |
| Corrosion resistance class (CRC) | 0 – No corrosion stress |
| Storage temperature | -20 °C … 70 °C |
| Relative air humidity | Non-condensing95 % |
| Degree of protection | IP20 |
| Ambient temperature | -5 °C … 50 °C |
| Certification | RCM compliance mark |
| Product weight | 96 g |
| Max. address capacity inputs | 8 byte |
| Data format | 15 bit + signLinear scaling |
| Max. cable length | Shielded30 m |
| Type of mounting | With H-rail |
| Note on materials | RoHS-compliantContains paint-wetting impairment substances |
| Housing material | PA |
| Weight | 0.239642 lbs |
|---|---|
| Dimensions | 6.692913 × 3.543307 × 1.181102 in |
Only logged in customers who have purchased this product may leave a review.




Reviews
There are no reviews yet