Dimensions W x L x H | 45 mm x 170 mm x 35 mm |
---|---|
KC characters | KC EMC |
Fieldbus interface, connection technology | M12x1, D-coded as per EN 61076-2-101 |
Diagnose per internal communication | Module errorOutput short circuit/overloadShort circuit/overload in sensor supplyLoad supply undervoltage |
Max. power supply | 2 x 4 A (external fuse required) |
Note on degree of protection | Unused connections sealed |
Communication interface, connection technology | M8x1, D-coded as per EN 61076-2-114 |
Fieldbus interface, connection type | 2x socket |
Permissible voltage fluctuations for electronics/sensors | ± 25 % |
Fieldbus interface, type | Ethernet |
Power supply, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Power supply, function | Incoming electronics/sensors and load |
Fieldbus interface, function | Bus connection, incoming/forwarding |
Information on max. cable length | Power supply according to nominal voltage |
Intrinsic current consumption at nominal operating voltage load | Typically 5 mA |
Voltage forwarding, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Diagnostics via bus | Load switch-offLoad overvoltageLoad undervoltageElectronics/sensors overvoltageElectronics/sensors undervoltageAPDD invalidCommunication with AP module interrupted |
Relative air humidity | 5 – 95 %Non-condensing |
Fieldbus interface, galvanic isolation | yes |
Communication interface, connection type | 2x socket |
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 90 mA |
Power supply, type of connection | Plug |
Voltage forwarding, connection type | Socket |
Communication interface, function | System communication XF20 OUT / XF21 OUT |
Fieldbus interface, protocol | EtherNet/IP |
Configuration support | EDS file |
Max. cable length | 50 m system communication |
Communication interface, protocol | AP-COM |
Fieldbus interface, transmission rate | 100 Mbit/s |
Diagnostics via LED | Diagnostics per moduleNetwork status Ethernet/IPPower supply for electronics/sensorsLoad power supplySystem diagnosticsMaintenance required |
Permissible voltage fluctuations load | ± 25 % |
Communication interface, shielding | yes |
Voltage forwarding, function | Outgoing electronics/sensors and load |
Fieldbus interface, number of poles/wires | 4 |
Max. address capacity outputs | 1324 byte |
Voltage forwarding, number of pins/wires | 4 |
Nominal operating voltage DC for electronics/sensors | 24 V |
Power supply, number of pins/wires | 4 |
Max. address capacity inputs | 1324 byte |
Communication interface, number of pins/wires | 4 |
Nominal operating voltage DC load | 24 V |
Power failure buffering | 10 ms |
Max. number of modules | 80 |
Note regarding operating voltage | SELV/PELV fixed power supplies requiredNote voltage drop |
Type code | CPX-AP-I |
Reverse polarity protection | yes |
CE marking (see declaration of conformity) | As per EU EMC directive |
Corrosion resistance class (CRC) | 1 – Low corrosion stress |
Storage temperature | -40 °C … 70 °C |
Degree of protection | IP65IP67 |
Ambient temperature | -20 °C … 50 °C |
Certification | RCM compliance mark |
Product weight | 194 g |
Type of mounting | With through-hole |
Note on materials | RoHS-compliant |
Housing material | PAPCDie-cast zinc, nickel-plated |