Dimensions W x L x H | 30 mm x 102.5 mm x 35 mm |
---|---|
KC characters | KC EMC |
Diagnose per internal communication | Short circuit/overload in sensor supplyElectronics/sensors overvoltageElectronics/sensors undervoltage |
Max. power supply | 2 x 4 A (external fuse required) |
Note on degree of protection | Unused connections sealed |
Fuse protection inputs (short circuit) | Internal electronic fuse per module |
Communication interface, connection technology | M8x1, D-coded as per EN 61076-2-114 |
Permissible voltage fluctuations for electronics/sensors | ± 25 % |
Power supply, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Power supply, function | Incoming electronics/sensors and load |
Relative air humidity | 5 – 95 %Non-condensing |
Communication interface, connection type | Socket |
Intrinsic current consumption at nominal operating voltage for electronics/sensors | Typically 32 mA |
Power supply, type of connection | Plug |
Communication interface, function | System communication XF10 IN |
Max. cable length | 30 m inputs50 m system communication |
Electrical connection input, function | Digital input |
Communication interface, protocol | AP-COM |
Digital inputs, electrical isolation of input – internal communication | yes |
Diagnostics via LED | Diagnostics per moduleStatus per channel |
Electrical isolation of inputs between channels | no |
Electrical connection input, connection type | 4x socket |
Communication interface, shielding | yes |
Electrical input connection, connection technology | M8x1, A-coded as per EN 61076-2-104 |
Electrical connection, input, number of pins/wires | 3 |
Nominal operating voltage DC for electronics/sensors | 24 V |
Power supply, number of pins/wires | 4 |
No. of inputs | 4 |
Communication interface, number of pins/wires | 4 |
Max. residual current of inputs per module | 0.8 A |
Power failure buffering | 10 ms |
Note regarding operating voltage | SELV/PELV fixed power supplies requiredNote voltage drop |
Type code | CPX-AP-I |
Reverse polarity protection | yes |
Input debounce time | 0.1 ms3 ms10 ms20 ms |
Switching level | Signal 0: <= 5 VSignal 1: >= 11 V |
CE marking (see declaration of conformity) | As per EU EMC directive |
Corrosion resistance class (CRC) | 1 – Low corrosion stress |
Storage temperature | -40 °C … 70 °C |
Degree of protection | IP65IP67 |
Ambient temperature | -20 °C … 50 °C |
Certification | RCM compliance mark |
Product weight | 81 g |
Input characteristics | As per IEC 61131-2, type 3 |
Input switching logic | PNP (positive switching)2-wire sensors as per IEC 61131-23-wire sensors as per IEC 61131-2 |
Type of mounting | With through-hole |
Note on materials | RoHS-compliant |
Housing material | PAPCDie-cast zinc, nickel-plated |
CPX-AP-I-4DI-M8-3P