MS6-SV-1/2-E-ASIS-AG

$1,690.96

Our soft start/quick exhaust valves MS6-SV cut off the power to critical components in the blink of an eye when an emergency stop is triggered. They also restart the system with the same care and reliability once the problem has been eliminated.

SKU: 8001480 Category: Tag:
Festo
Series MS
KC characters KC EMC
For use in the food industry See supplementary material information
Size 6
Width dimension 62 mm
Type code MS6-SV
Safety function Prevention of unexpected start-up (pressurization)Exhausting
Safety integrity level (SIL) Avoidance of unexpected start-up (pressurization)/SIL 3Exhaust/SIL 3
Performance Level (PL) Avoidance of unexpected start-up (pressurization)/up to category 4, performance level eExhaust/up to category 4, performance level e
Note on forced dynamization Switching frequency at least once a month
Design Piston seat
Underlap no
Actuation type Electrical
Pilot air supply port Internal
Sealing principle Soft
Exhaust air function Without flow control option
Position sensing principle Piston magnet principle
Conforms to standard DIN EN ISO 13849-1
Manual override None
Reset method Mechanical spring
Type of control Pilot-controlled
Symbol 995704
Valve function Pressure build-up function3/2, closed, monostable
Pressure gauge with pressure gauge
C value 19.3 l/sbar
b-value 0.21
Standard nominal flow rate 4300 l/min
Standard flow rate exhaust 6-> 0 bar 9000 l/min
Max. switching frequency 1 Hz
Switching time off 40 ms
On switching time 130 ms
Duty cycle 1
Signal status display Via AS-iLED
Operating medium Compressed air as per ISO 8573-1:2010 [7:4:4]
Information on operating and pilot media Operation with oil lubrication possible (required for further use)
Corrosion resistance class (CRC) 2 – Moderate corrosion stress
Note on materials RoHS-compliant
Degree of protection With plug socketIP65
Temperature of medium 0 °C … 50 °C
Ambient temperature 0 °C … 50 °C
Storage temperature 0 °C … 50 °C
Shock resistance Shock test with severity level 2 as per FN 942017-5 and EN 60068-2-27
Vibration resistance Transport application test with severity level 2 as per FN 942017-4 and EN 60068-2-6
Certification RCM compliance mark
Certificate issuing authority German Technical Control Board (TÃœV) 44 799 12 556236 000
CE marking (see declaration of conformity) as per EU machinery directiveAs per EU EMC directive
Type of mounting Optionally:Line installationWith accessories
Mounting position Any
Product weight 2000 g
Pneumatic connection 1 G1/2
Pneumatic connection 2 G1/2
Pneumatic connection 3 G1
Electrical connection 2x M12
Product identification Profile: 7.5.5ID1: 0xFID code: 0x5ID2:0x5I/O code: 0x7
Vendor ID AS-interface 0x014D
Device ID AS-interface 0x03A6
Fieldbus interface Plug, M12 (AS-i In)Socket, M12 (AS-i Out)
Device-specific diagnostics Cyclic analog valuesCyclic digital data inputsAcyclic values
AS-Interface DC operating voltage range 22 V … 31.6 V
Addressing range Standard slave: 1 … 31
LED indicators AS-iStatus
Housing material Die-cast aluminum
Seals material NBR
Piston rod material High-alloy stainless steel

Coast Pneumatics